Fire Door Manufacturing. Bespoke Solutions.
Preventr fire doors are BMTRADA Q-Mark Certified and manufactured in the UK bespoke to regulatory standards.
Gold Standard Accreditations
Preventr designs, manufactures, and installs BMTRADA Q-Mark certified fire doors to the highest safety standards. We also provide repair, maintenance, and compliance verification, ensuring that every doorset protects lives and property and exceeds current regulation requirements.
Explore Our fire door system
Fire doorsets for every requirement
Communal FD30 Fire
Door Sets
Certified FD30 fire doors designed for communal areas, providing 30 minutes of fire resistance. Durable, compliant, and expertly installed to protect residents and property.
Communal FD60
Fire Door Sets
High-performance FD60 fire doors offering 60 minutes of fire resistance for communal spaces. Engineered for safety, durability, and full regulatory compliance.
SBD / PAS 24 Security-
Rated Door Sets
Fire doors tested to SBD and PAS 24 standards for enhanced security and fire safety. Ideal for entry points where both protection and compliance are essential.
Bespoke
Configurations
Front entrance Fire doors
Preventr® Westminister
Preventr® Vanguard
Preventr® Devonshire
Preventr® Soho
Preventr® Sutherland
Preventr® Sovereign
Preventr® Churchill
Preventr® Argyll
Fire Doorset Finishes
Our manufactured fire doors range is available in a range of high-quality finishes to suit any interior or exterior environment. Choose from extensive standard colours, wood veneers, or bespoke finishes tailored to your project. All finishes are durable, compliant, and designed to maintain performance over time. Discuss your bespoke requirements with one our estimators.
Laminate & veneer Fire doors
Hospital / Clinical PVC-wrapped Fire doors
Painted finish Fire doors
With 30 years of manufacturing experience, Preventr’s fire door manufacturing division produces doors that meet the highest standards of quality and compliance – BM TRADA Q-Mark certified, CNC-precision engineered, and backed by ISO processes applied rigorously at every stage of production.
Mick Coulthard, Head of Fire Door Manufacturing
Certification & testing
All Preventr fire door manufacturing is certified under the BM TRADA Q-Mark scheme, ensuring independent third-party verification of performance and compliance.
We hold our own primary test evidence.
Each product is rigorously tested and manufactured in line with certified processes and strict quality controls. Full documentation and traceability are provided, giving complete confidence in compliance and long-term reliability.
As part of our fire door manufacturing process, each fire door is fitted with a QR tag, to ensure the golden thread is maintained throughout the lifecycle of the asset, and updated during installation and regular maintenance inspections.
Why choose Preventr
30+ years in the fire door manufacturing and installation industry, with a dedicated team of technical experts, on-hand to support you with your project.
Fire door manufacturing matters because it ensures full control over quality, consistency, and compliance from the very start.
By producing fire doorsets in-house, we guarantee every component meets certified standards and performs as intended.
This approach reduces risk, improves traceability, and delivers reliable, compliant solutions you can trust – improving the fire stopping ability of your building.
Lead time & supply
All fire door manufacturing is certified under the BMTRADA Q-Mark scheme, ensuring independent third-party verification of performance and compliance.
We hold our own primary test evidence for our range of fire doors.
Each product is rigorously tested and manufactured in line with certified processes and strict quality controls. Full documentation and traceability are provided, giving complete confidence in compliance and long-term reliability.
Preventr uses the latest AI-powered technology in our manufacturing facility to guarantee lead times of 3-6 weeks with national delivery and installation teams to support your project.
Get A Quote
Speak to our fire door experts today and take the next step towards full compliance. Fast, reliable, and fully accountable fire protection starts here.
Fire Doors: Technical Guide
What is a fire door?
A fire door is a tested assembly designed to resist the passage of fire and, where specified, smoke for a defined period. It is a structural component of a building’s compartmentation strategy, not a door with a rating attached to it.
Its performance depends on every element working together: the core, the facings, the lippings, the frame, the intumescent and smoke seals, the hinges, the latch, the closer and any glazing. Each of those was present when the door was tested, and each must be present, correct and correctly installed for the rating to hold.
Fire doors serve two purposes. They protect escape routes so occupants can leave, and they maintain compartmentation so fire cannot spread beyond its compartment of origin within the required period. A fire door is the only part of a compartment wall designed to be opened, which is precisely why it is the part most likely to fail.
In UK regulation, fire doors sit within Requirement B1 and B3 of the Building Regulations, are addressed in Approved Document B, and — in residential buildings above 11 metres — carry specific inspection duties under the Fire Safety (England) Regulations 2022.
Fire door ratings explained: FD30, FD60, FD90 and FD120
The FD designation indicates the period in minutes for which the doorset resisted fire under test.
- FD30 — 30 minutes. The most common rating in the UK, used for flat entrance doors, room doors onto protected corridors and most general compartmentation.
- FD60 — 60 minutes. Used where longer resistance is required: protected stairwells in taller buildings, plant and service risers, and higher-risk compartment lines.
- FD90 — 90 minutes. Typically industrial, plant and specialist applications.
- FD120 — 120 minutes. High-risk separation, and specific industrial and infrastructure settings.
An S suffix — FD30S, FD60S — denotes additional smoke control performance, requiring smoke seals and a controlled threshold gap. Smoke, not fire, is the principal cause of death in building fires, and most doors on escape routes in residential buildings require smoke control performance.
The rating alone does not establish compliance. A door is compliant when it carries the required rating and the supporting test evidence covers the specific configuration supplied — leaf size, glazing, ironmongery and frame. The evidence, not the label, is what a specifier or building control body will examine.
Our range of fire doors
Preventr manufactures certified timber fire doorsets at our facility in Crigglestone, Wakefield, using CNC machining with in-house ironmongery preparation.
- Fire ratings: FD30, FD60, FD90 and FD120 under BMTRADA Q Mark
- Smoke control: intumescent and smoke seals fitted as standard across the range
- Acoustic doorsets: manufactured to specified acoustic ratings using appropriate cores, acoustic seals and drop-down threshold seals, available fire-rated to FD30 and FD60
- Mechanical duty: severe duty classification
- Glazed doorsets: fire-rated vision panels and glazing within tested scope
- Sizes: standard and bespoke, manufactured to survey dimensions
- Finishes: PVC-wrapped, veneer, paint-grade and laminate options
- Flat entrance doorsets: PAS 24 secured by design (fire and smoke)
All fire doors are supplied as complete units — leaf, frame, seals and ironmongery certified together — rather than as components to be assembled on site.
Doorsets or door leaves: what you are actually buying
A fire doorset is a complete factory-assembled unit, tested and certified as one. A door assembly is built on site from separately sourced components, each possibly certified individually but not necessarily tested together.
The distinction is not commercial hairsplitting. Fire resistance is a property of the tested combination. Fitting a certified leaf into an uncertified frame, or substituting a hinge outside the tested scope, produces an assembly with no valid evidence behind it — even where every individual component carries a certificate.
Doorsets move that risk into the factory, where the leaf-to-frame relationship, the seal housings, the ironmongery preparation and the tolerances are controlled and recorded. On site, the installer’s responsibility narrows to fixing the unit correctly into the structural opening.
Refurbishment raises this repeatedly. Retaining an existing frame and replacing only the leaf produces an assembly whose combined performance is usually unknown, because the frame’s original specification has been lost. Where evidence cannot be established, full doorset replacement is generally the only defensible route.
How certified fire doors are manufactured
Fire door manufacturing is a controlled sequence, each stage of which is defined by the test evidence rather than by preference.
Specification and survey. Structural opening dimensions, required rating, smoke control requirement, acoustic requirement, ironmongery schedule and finish are established and checked against the tested scope before anything is cut.
Core selection. The core determines the fire performance and must be the type used in the test. Cores are not interchangeable between ratings.
Facing and lipping. Facings are bonded to the core and hardwood lippings applied to the edges, to the dimensions and species within the tested configuration.
Machining. CNC machining cuts the leaf to size and prepares hinge, lock and closer positions to tolerance. Maximum permitted leaf sizes are set by the test evidence, and oversizing is one of the most common routes to an invalid certification.
Seal installation. Intumescent and, where required, smoke seals are routed into leaf or frame to the tested configuration, continuous along head and stiles.
Frame manufacture and hanging. The frame is machined, seals fitted, and the leaf hung and adjusted so gap tolerances are achieved in the factory rather than on site.
Inspection, labelling and record. Each doorset is inspected, labelled with its certification reference, and recorded against its project and location.
All Preventr fire doors are manufactured in-house at our factory in Wakefield, Yorkshire which has been established for over 30 years.
BS 476 is being withdrawn: what it means for fire doors specified today
This is the most consequential change facing fire door specification in the UK, and it affects doors being ordered now.
Historically UK fire doors could demonstrate performance by either route: the national classes under the BS 476 series, or the European classes under BS EN 1634-1 with classification to BS EN 13501-2. Following scrutiny of the national system during the Grenfell Tower Inquiry, the government confirmed the withdrawal of BS 476 from Approved Document B.
The reaction-to-fire elements were removed in March 2025. A five-year coexistence period for fire resistance, which includes fire doorsets, runs until 2 September 2029. From that date, only BS EN 13501-2 and BS EN 1634-1 evidence will be accepted for demonstrating compliance in new work.
Two practical consequences follow. First, BS 476-22 evidence has a finite life, and a manufacturer relying on it faces a retesting programme, with testing capacity across the industry under pressure. Second, EN 1634-1 is a more demanding test method, so existing performance cannot be assumed to transfer.
What EI 30 and E 60 mean under BS EN 13501-2
European classification for fire doors expresses performance as criteria plus a period in minutes.
- E — Integrity. Flames and hot gases are prevented from passing through.
- I — Insulation. Temperature rise on the unexposed face is limited, so material on the far side cannot ignite.
- W — Radiation. Radiated heat through the element is limited.
- Sa / S200 — Smoke leakage. Ambient and medium-temperature smoke control performance.
So EI2 30 denotes 30 minutes of integrity and insulation. E 30 Sa denotes 30 minutes of integrity with ambient smoke control but no insulation requirement.
The mapping to the familiar FD notation is not exact. FD30 broadly corresponds to E 30 or EI 30 depending on the insulation requirement, and FD30S to E 30 Sa. Specifiers moving to the European system should state the classification required rather than the FD equivalent, because the insulation criterion is a genuine performance difference and is significantly harder to achieve.
The end of desktop assessments: Direct and Extended Application
Historically, variation from a tested doorset — a different leaf size, an additional vision panel, a different ironmongery cutout — could be justified by an assessment report, sometimes referred to as a desktop study, in which a competent consultant gave written opinion that the change would not reduce performance.
That route is closing. Under the European regime, variation must be justified either within Direct Application rules, which are the permitted variations defined within the test standard itself, or by a formal Extended Application report prepared to defined rules and supported by test data.
For specifiers, this means bespoke variations require more rigorous justification and, in some cases, additional testing. For manufacturers, it means the breadth of the tested range matters more than it did, because what falls outside it can no longer be covered by opinion.
Practically, two questions of any bespoke doorset should be asked: what is the maximum permitted leaf size under the test evidence, and is the glazing and ironmongery configuration within Direct Application, or does it require an Extended Application report?
BM TRADA Q-Mark: what our fire door certification covers
Q-Mark operates as separate schemes, each independently assessed: fire door manufacture, fire door installation, fire door maintenance and fire door inspection. Holding one confers nothing about the others, and suppliers claiming “Q-Mark accredited” without specifying scope should be asked which.
Certification under the manufacturing scheme assesses the factory’s quality management, production control, incoming material verification, machining tolerances and finished product, through unannounced surveillance audits. Certified doorsets carry a label or plug identifying the scheme, the manufacturer and a unique reference, allowing any door to be traced back to its production record.
Preventr holds BM TRADA Q-Mark certification for fire door manufacturing (certificate 1385), fire door installation and fire door maintenance.
Holding all three matters for a practical reason rather than a presentational one. Where manufacture, installation and maintenance of fire doors sit with a single certificated organisation, responsibility for the doorset’s compliance does not fragment across three suppliers with three scopes and no shared record. If a door fails inspection in year four, the manufacturing record, the installation evidence and the maintenance history are in one place.
Fire door labelling, traceability and the golden thread
A certified fire door must be traceable back to its evidence for the life of the building. That requires a durable identification on the door and a record behind it.
Certified fire doors carry a label or colour-coded plug, generally to the top edge of the leaf, identifying the manufacturer, the certification scheme and a unique reference. The identification must survive installation and decoration — labels painted over, filled or removed leave a door that may be entirely compliant but cannot be shown to be.
Behind the label sits the record: the specification, the test evidence relied upon, the ironmongery schedule, the manufacturing date and the location the door was supplied to.
This is the substance of the golden thread requirement introduced by the Building Safety Act 2022 for higher-risk buildings, and of the Regulation 38 duty to hand fire safety information to the responsible person at completion. BS 8644-1 sets out how such information should be structured digitally.
Preventr records manufacturing, installation and maintenance data through our digital compliance portal, so a door’s history remains accessible across successive inspection cycles rather than sitting in a handover PDF that is filed once and lost.
Mechanical duty, durability and fire door strength classification
Fire performance is only one axis. A door in a hospital corridor or a school circulation route will take severe mechanical abuse, and a door that has been damaged, distorted or forced no longer performs as tested.
Mechanical duty is classified under BS EN 1192, which defines strength classes for doorsets. This superseded the older DD 171, which is now withdrawn — specifications and product literature still citing DD 171 should be updated.
Specify mechanical duty alongside fire rating in high-traffic settings. A doorset that is correctly fire rated but under-specified mechanically will require earlier replacement, and in the interim will generate a stream of maintenance defects — damaged lippings, distorted leaves, failed closers — each of which is a compliance finding.
Acoustic and dual-rated fire doors
Many settings require both fire and acoustic performance from the same doorset — residential flat entrance doors, hotel bedrooms, consulting rooms, teaching spaces and offices.
The two requirements interact. Acoustic performance of fire doors depends on mass, on continuous seals and on a sealed threshold, which typically means a drop-down seal. Fire performance depends on the tested core, the intumescent seals and the gap tolerances. A doorset must satisfy both, and the combination must be within a tested scope for fire.
Acoustic performance is expressed as a sound reduction index in decibels, and the figure achieved in a laboratory is not the figure achieved on site — installation, threshold detail and flanking transmission all reduce it. Specify the laboratory rating and design the installation detail to protect it.
Preventr manufactures fire-rated acoustic fire doors in standard and bespoke sizes, using appropriate cores, perimeter acoustic seals and drop-down threshold seals.
Glazing, vision panels and ironmongery in fire door manufacturing
Glazing. Fire-resisting glazing is a tested system: the glass, the intumescent glazing seal, the beads and the fixings, in the configuration tested. Integrity-only glass and insulating glass are not interchangeable, and the required specification depends on the door’s role in the escape strategy. Aperture size and position are constrained by the test evidence.
Vision panels must be manufactured into our fire doors, not cut into a finished leaf on site. Site-cut apertures void certification and are a recurring finding in refurbishment work.
Ironmongery. All essential ironmongery must fall within the tested scope. Hinges must be fire-rated, generally a minimum of three, conforming to BS EN 1935. Closers must conform to BS EN 1154 and be capable of closing and latching the door from any open position. Panic and emergency exit hardware conforms to BS EN 1125 and BS EN 179 respectively. Mortices for locks, latches and hinges generally require intumescent protection as tested.
Preparing ironmongery in the factory rather than on site removes a substantial source of non-compliance, because the cutouts are machined to the tested dimensions and the compatibility question is resolved before the doorset leaves the works.
Specifying a fire door: what we need from you
To quote and manufacture accurately we need:
- Fire rating and smoke control requirement for each opening, taken from the fire strategy or fire risk assessment
- Structural opening dimensions, ideally from survey rather than drawing
- Wall construction — masonry, metal stud, timber stud — since fixing and certification scope depend on substrate
- Door configuration — single, double, leaf-and-a-half, with or without over-panel or side-light
- Glazing requirement, including aperture size and position
- Ironmongery schedule, including closer type, locking, access control and any hold-open devices
- Acoustic requirement, where applicable
- Mechanical duty, based on traffic and setting
- Finish and any colour or veneer matching requirement
- Security requirement, where Approved Document Q or a client standard applies
Where a fire strategy is unavailable or the existing doors are of unknown specification, a fire door survey establishes the asset register and the required ratings before manufacture begins.
Lead times, capacity and programme delivery
Lead time is usually the binding constraint on fire doors replacement programmes, particularly where installation depends on resident or clinical access appointments that must be booked in advance.
Manufacturing in-house allows production to be sequenced against the access programme rather than the reverse. Fire doors can be batched by block, floor or wing and released to match the installation schedule, which reduces on-site storage — a genuine problem in occupied residential buildings — and avoids the situation where access has been secured but doors have not arrived.
It also means variation can be absorbed. Surveys routinely reveal openings that differ from record drawings, and a bespoke doorset can be produced without restarting a procurement cycle.
Preventr maintains lead times of 3-6 weeks for bespoke manufacturing and installation of fire doors.